minitor-go/README.md

191 lines
8.3 KiB
Markdown

# [minitor-go](https://git.iamthefij.com/iamthefij/minitor-go)
A minimal monitoring system
## What does it do?
Minitor accepts a YAML configuration file with a set of commands to run and a set of alerts to execute when those commands fail. It is designed to be as simple as possible and relies on other command line tools to do checks and issue alerts.
## But why?
I'm running a few small services and found Sensu, Consul, Nagios, etc. to all be far too complicated for my usecase.
## So how do I use it?
### Running
Install and execute with:
```bash
go get github.com/iamthefij/minitor-go
minitor
```
If locally developing you can use:
```bash
make run
```
It will read the contents of `config.yml` and begin its loop. You could also run it directly and provide a new config file via the `-config` argument.
#### Docker
You can pull this repository directly from Docker:
```bash
docker pull iamthefij/minitor-go:latest
```
The Docker image uses a default `config.yml` that is copied from `sample-config.yml`. This won't really do anything for you, so when you run the Docker image, you should supply your own `config.yml` file:
```bash
docker run -v $PWD/config.yml:/app/config.yml iamthefij/minitor-go:latest
```
Images are provided for `amd64`, `arm`, and `arm64` architechtures.
Timezone configuration for the container is set by passing the `TZ` env variable. Eg. `TZ=America/Los_Angeles`.
## Configuring
In this repo, you can explore the `sample-config.yml` file for an example, but the general structure is as follows. It should be noted that environment variable interpolation happens on load of the YAML file.
The global configurations are:
|key|value|
|---|---|
|`check_interval`|Maximum frequency to run checks for each monitor as duration, eg. 1m2s.|
|`default_alert_after`|A default value used as an `alert_after` value for a monitor if not specified or 0.|
|`default_alert_down`|Default down alerts to used by a monitor in case none are provided.|
|`default_alert_up`|Default up alerts to used by a monitor in case none are provided.|
|`monitors`|List of all monitors. Detailed description below|
|`alerts`|List of all alerts. Detailed description below|
### Monitors
All monitors should be listed under `monitors`.
Each monitor allows the following configuration:
|key|value|
|---|---|
|`name`|Name of the monitor running. This will show up in messages and logs.|
|`command`|Specifies the command that should be executed, either in exec or shell form. This command's exit value will determine whether the check is successful|
|`alert_down`|A list of Alerts to be triggered when the monitor is in a "down" state|
|`alert_up`|A list of Alerts to be triggered when the monitor moves to an "up" state|
|`check_interval`|The interval at which this monitor should be checked. This must be greater than the global `check_interval` value|
|`alert_after`|Allows specifying the number of failed checks before an alert should be triggered|
|`alert_every`|Allows specifying how often an alert should be retriggered. There are a few magic numbers here. Defaults to `-1` for an exponential backoff. Setting to `0` disables re-alerting. Positive values will allow retriggering after the specified number of checks|
### Alerts
Alerts exist as objects keyed under `alerts`. Their key should be the name of the Alert. This is used in your monitor setup in `alert_down` and `alert_up`.
Eachy alert allows the following configuration:
|key|value|
|---|---|
|`command`|Specifies the command that should be executed, either in exec or shell form. This is the command that will be run when the alert is executed. This can be templated with environment variables or the variables shown in the table below|
Also, when alerts are executed, they will be passed through Go's format function with arguments for some attributes of the Monitor. The following monitor specific variables can be referenced using Go formatting syntax:
|token|value|
|---|---|
|`{{.AlertCount}}`|Number of times this monitor has alerted|
|`{{.FailureCount}}`|The total number of sequential failed checks for this monitor|
|`{{.LastCheckOutput}}`|The last returned value from the check command to either stderr or stdout|
|`{{.LastSuccess}}`|The datetime of the last successful check as a go Time struct|
|`{{.MonitorName}}`|The name of the monitor that failed and triggered the alert|
|`{{.IsUp}}`|Indicates if the monitor that is alerting is up or not. Can be used in a conditional message template|
To provide flexible formatting, the following non-standard functions are available in templates:
|func|description|
|---|---|
|`ANSIC <Time>`|Formats provided time in ANSIC format|
|`UnixDate <Time>`|Formats provided time in UnixDate format|
|`RubyDate <Time>`|Formats provided time in RubyDate format|
|`RFC822Z <Time>`|Formats provided time in RFC822Z format|
|`RFC850 <Time>`|Formats provided time in RFC850 format|
|`RFC1123 <Time>`|Formats provided time in RFC1123 format|
|`RFC1123Z <Time>`|Formats provided time in RFC1123Z format|
|`RFC3339 <Time>`|Formats provided time in RFC3339 format|
|`RFC3339Nano <Time>`|Formats provided time in RFC3339Nano format|
|`FormatTime <Time> <string template>`|Formats provided time according to provided template|
|`InTZ <Time> <string timezone name>`|Converts provided time to parsed timezone from the provided name|
For more information, check out the [Go documentation for the time module](https://pkg.go.dev/time@go1.20.7#pkg-constants).
### Metrics
Minitor supports exporting metrics for [Prometheus](https://prometheus.io/). Prometheus is an open source tool for reading and querying metrics from different sources. Combined with another tool, [Grafana](https://grafana.com/), it allows building of charts and dashboards. You could also opt to just use Minitor to log check results, and instead do your alerting with Grafana.
It is also possible to use the metrics endpoint for monitoring Minitor itself! This allows setting up multiple instances of Minitor on different servers and have them monitor each-other so that you can detect a minitor outage.
To run minitor with metrics, use the `-metrics` flag. The metrics will be served on port `8080` by default, though it can be overriden using `-metrics-port`. They will be accessible on the path `/metrics`. Eg. `localhost:8080/metrics`.
```bash
minitor -metrics
# or
minitor -metrics -metrics-port 3000
```
## Contributing
Whether you're looking to submit a patch or tell me I broke something, you can contribute through the Github mirror and I can merge PRs back to the source repository.
Primary Repo: https://git.iamthefij.com/iamthefij/minitor.git
Github Mirror: https://github.com/IamTheFij/minitor.git
## Original Minitor
This is a reimplementation of [Minitor](https://git.iamthefij.com/iamthefij/minitor) in Go
Minitor is already a minimal monitoring tool. Python 3 was a quick way to get something live, but Python itself comes with a large footprint. Thus Go feels like a better fit for the project, longer term.
Initial target is meant to be roughly compatible requiring only minor changes to configuration. Future iterations may diverge to take advantage of Go specific features.
### Differences from Python version
Templating for Alert messages has been updated. In the Python version, `str.format(...)` was used with certain keys passed in that could be used to format messages. In the Go version, we use a struct, `AlertNotice` defined in `alert.go` and the built in Go templating format. Eg.
minitor-py:
```yaml
alerts:
log:
command: 'echo {monitor_name}'
```
minitor-go:
```yaml
alerts:
log:
command: 'echo {{.MonitorName}}'
```
Interval durations have changed from being an integer number of seconds to a duration string supported by Go, for example:
minitor-py:
```yaml
check_interval: 90
```
minitor-go:
```yaml
check_interval: 1m30s
```
For the time being, legacy configs for the Python version of Minitor should be compatible if you apply the `-py-compat` flag when running Minitor. Eventually, this flag will go away when later breaking changes are introduced.
## Future
Future, potentially breaking changes
- [ ] Consider value of templating vs injecting values into Env variables
- [ ] Async checking
- [ ] Revisit metrics and see if they all make sense
- [ ] Consider dropping `alert_up` and `alert_down` in favor of using Go templates that offer more control of messaging (Breaking)