import pytest
|
|
|
|
from minitor.main import InvalidMonitorException
|
|
from minitor.main import MinitorAlert
|
|
from minitor.main import Monitor
|
|
from minitor.main import validate_monitor_settings
|
|
|
|
|
|
class TestMonitor(object):
|
|
|
|
@pytest.fixture
|
|
def monitor(self):
|
|
return Monitor({
|
|
'name': 'SampleMonitor',
|
|
'command': ['echo', 'foo'],
|
|
})
|
|
|
|
@pytest.mark.parametrize('settings', [
|
|
{'alert_after': 0},
|
|
{'alert_every': 0},
|
|
{'check_interval': 0},
|
|
{'alert_after': 'invalid'},
|
|
{'alert_every': 'invalid'},
|
|
{'check_interval': 'invalid'},
|
|
])
|
|
def test_monitor_invalid_configuration(self, settings):
|
|
with pytest.raises(InvalidMonitorException):
|
|
validate_monitor_settings(settings)
|
|
|
|
@pytest.mark.parametrize(
|
|
'alert_after',
|
|
[1, 20],
|
|
ids=lambda arg: 'alert_after({})'.format(arg),
|
|
)
|
|
@pytest.mark.parametrize(
|
|
'alert_every',
|
|
[-1, 1, 2, 1440],
|
|
ids=lambda arg: 'alert_every({})'.format(arg),
|
|
)
|
|
def test_monitor_alert_after(self, monitor, alert_after, alert_every):
|
|
monitor.alert_after = alert_after
|
|
monitor.alert_every = alert_every
|
|
|
|
# fail a bunch of times before the final failure
|
|
for _ in range(alert_after - 1):
|
|
monitor.failure()
|
|
|
|
# this time should raise an alert
|
|
with pytest.raises(MinitorAlert):
|
|
monitor.failure()
|
|
|
|
@pytest.mark.parametrize(
|
|
'alert_after',
|
|
[1, 20],
|
|
ids=lambda arg: 'alert_after({})'.format(arg),
|
|
)
|
|
@pytest.mark.parametrize(
|
|
'alert_every',
|
|
[1, 2, 1440],
|
|
ids=lambda arg: 'alert_every({})'.format(arg),
|
|
)
|
|
def test_monitor_alert_every(self, monitor, alert_after, alert_every):
|
|
monitor.alert_after = alert_after
|
|
monitor.alert_every = alert_every
|
|
|
|
# fail a bunch of times before the final failure
|
|
for _ in range(alert_after - 1):
|
|
monitor.failure()
|
|
|
|
# this time should raise an alert
|
|
with pytest.raises(MinitorAlert):
|
|
monitor.failure()
|
|
|
|
# fail a bunch more times until the next alert
|
|
for _ in range(alert_every - 1):
|
|
monitor.failure()
|
|
|
|
# this failure should alert now
|
|
with pytest.raises(MinitorAlert):
|
|
monitor.failure()
|
|
|
|
def test_monitor_alert_every_exponential(self, monitor):
|
|
monitor.alert_after = 1
|
|
monitor.alert_every = -1
|
|
|
|
failure_count = 16
|
|
expect_failures_on = {1, 2, 4, 8, 16}
|
|
|
|
for i in range(failure_count):
|
|
if i + 1 in expect_failures_on:
|
|
with pytest.raises(MinitorAlert):
|
|
monitor.failure()
|
|
else:
|
|
monitor.failure()
|